71
ULM.0.01.000RE_10_08_20
At temperature of levelmeters flange
higher than 50˚ C
It’s required placement of radio-
transparent isolating seal
Atmosphere pressure
84,0…106,7 kPa (630-800 mm Hg)
Realtive humidity in installation location
of levelmeter
Not more than 95% at 35˚ C and lower
temperatures, without moisture conden-
sation
Overpressure or underpressure in tank
-1…6 bar, it’s required placement of ra-
dio-transparent seal
Mechanical stresses
- vibration with amplitude
- frequency
Not more than 0,1 mm
5…25Hz
Maximal inclination of vertical axis of
levelmeter
2 degree
Protecting
Protecting from penetrating of moisture
and dust
IP65
Kind of body
General industrial (not explosion proof)
Power
Power supply
24…36V DC
Connection type
2-wire
Maximal power consumption
0,8 W
Electro-mechanical data
Cable glands
Option 1:
1 cable gland M20х1,5 (round cable with
diameter Ø 8…13 mm)
1. plug M20х1,5
Option 2:
2 cable glands M20х1,5 (round cable
Ø 8…13 mm)
Screw contacts for electrical connection
of wires wits cross section
Not more than 2,5 mm (AWG 14)
Содержание ULM-31-HF
Страница 28: ...28 ULM 0 01 000RE_10_08_20 Fig 4 12 Examples of Installation ...
Страница 74: ...74 ULM 0 01 000RE_10_08_20 12 5 Mounting of ULM 31А1 level transmitter at the stub tube ...
Страница 76: ...76 ULM 0 01 000RE_10_08_20 12 7 Mounting of ULM 31 HF ULM 31А1 HF level transmitters at the stub tube ...
Страница 77: ...77 ULM 0 01 000RE_10_08_20 12 8 Mounting of ULM 31А1 level transmitter at the stub tube with insulating spacer ...
Страница 83: ...83 ULM 0 01 000RE_10_08_20 12 14 Mounting flange ...