70
ULM.0.01.000RE_10_08_20
12.2 Specifications of levelmeter ULM-31A1-HF-F-LC, 2-wire option.
Name
Specification
General information
Body material
Aluminium casting alloy, electroplated
anodizing,
powder coating
Sealing material between body and cov-
er
Rubber
Antenna screen material
Teflon
Cable glands material
Polyamide
Weight without flange
Not more than 2,5Kg
Dimensions
203х103х153 mm
Kind of mounting
Flange
Not less
than DN 50
Analog output
4-20mA
Total load
Not more than 300 ohm
Error(in temperature range(-40…+50°C) Not more 0,25% of measuring range
Digital output
It’s used HART modem for configura-
tion
Resolution
0,1 mm
Working specifications
Absolute error
± 5 mm
Measuring range
0,6…15 m
Recommended application
Measuring of liquids
Measuring range with reduced precision 0,3…0,6 m
Operating principle
Radar for measuring level,
using FMCW
Working frequency
125±5 GHz
Radiated power
Not more than 1mW
Antenna pattern width
5˚
Number of measurement per second
Not less than 6
Operating conditions
Ambient temperature in place of lev-
elmeter installation
-40 … +60˚ C
Содержание ULM-31-HF
Страница 28: ...28 ULM 0 01 000RE_10_08_20 Fig 4 12 Examples of Installation ...
Страница 74: ...74 ULM 0 01 000RE_10_08_20 12 5 Mounting of ULM 31А1 level transmitter at the stub tube ...
Страница 76: ...76 ULM 0 01 000RE_10_08_20 12 7 Mounting of ULM 31 HF ULM 31А1 HF level transmitters at the stub tube ...
Страница 77: ...77 ULM 0 01 000RE_10_08_20 12 8 Mounting of ULM 31А1 level transmitter at the stub tube with insulating spacer ...
Страница 83: ...83 ULM 0 01 000RE_10_08_20 12 14 Mounting flange ...