21
ULM.0.01.000RE_10_08_20
For example. With the hopper is 15 m high, is mounted at 1.6 m distance fro the
center. Using the Table, let us determine the required inclination angle 6˚.
- for device protection against direct sunlight in conditions of hot climate, the pro-
tection screen or the shed should be used;
Fig. 4.6. Installation of Device with Protection Screen
- the temperature in the level transmitter installation location shall not exceed
+50°С; the radio transparent sealing gasket should be used during the device instal-
lation on the tank with high ambient temperature (see paras 12.5, 12.6);
- the radio transparent sealing gasket should be used during the level transmitter in-
stallation on the tank with excessive pressure or vacuum (see paras 12.5, 12.6);
In case the device is used on the tank, where it is impossible to maintain the installa-
tion conditions on the absence of structures in the measuring beam, the following
recommendations should be adhered to:
- the distance from the tank wall to the level transmitter central axis shall be select-
ed within the limits 1/2 to 1/3 of the tank radius (See Fig. 4.7);
NOTE