29
ULM.0.01.000RE_10_08_20
4.7. Structures in Tank
The structures located in the tank - tubes, valves, stirrers, tank corrugated walls,
level alarms and other subjects may be the sources of the stray signal. The installa-
tion position of the level transmitter shall be selected so, that there are no obstacles
on the radio signal propagation way. If it is impossible to meet this condition due to
the tank design features, you should address the manufacturer's technical support
desk.
The impact of the design features can be reduced by using the inclined reflectors,
which dissipate the radio signal. The reflectors can be made of sheet metal.
Fig. 4.13. Example of inclined reflector above the structure in the tank
Содержание ULM-31-HF
Страница 28: ...28 ULM 0 01 000RE_10_08_20 Fig 4 12 Examples of Installation ...
Страница 74: ...74 ULM 0 01 000RE_10_08_20 12 5 Mounting of ULM 31А1 level transmitter at the stub tube ...
Страница 76: ...76 ULM 0 01 000RE_10_08_20 12 7 Mounting of ULM 31 HF ULM 31А1 HF level transmitters at the stub tube ...
Страница 77: ...77 ULM 0 01 000RE_10_08_20 12 8 Mounting of ULM 31А1 level transmitter at the stub tube with insulating spacer ...
Страница 83: ...83 ULM 0 01 000RE_10_08_20 12 14 Mounting flange ...