background image

1

ON

1  2

ON

1  2

XRF-1

 50 

 121 

 23 

5

 50 

 121 

 23 

5

 50 

 125 

 23 

 106 

 22

ON

1  2

 50 

 125 

 23 

 106 

 22

ON

1  2

 50 

 121 

 23 

 4.2 

 5.7 

 4.2 

 22 

 106 

 50 

 121 

 23 

 5.7 

 4.2 

 4.2 

 22 

 106 

LED 1

LED

Wireless single channel signal transmission system for safety edges 

Original operating instructions

Intended use: Monitoring safety edges on doors and gates

1

Safety instructions

ENGLISH

404169C

07/20

Transmitter (Tx)

Receiver (Rx)

•  Read these operating instructions thoroughly before putting the device into 

operation and keep them for future reference.

•  The assembly, commissioning, modifications and extensions may only be comple-

ted by an experienced electrician.

•  Before commencing work, remove the power supply from the device/installations!

•  During the operation of electrical components 

– e. g. in the case of a short circuit hot and ionised gases can be

 

emitted 

– protection covers must not to be removed.

•  Pay attention to all local relevant electrical safety regulations.

•  Disregard of the safety regulations can cause death, severe injuries or extensive 

damage.

•  Devices that are classified as Category 2 according to EN ISO 13849-1 must be 

tested regularly – at least once per cycle.

•  It is the responsibility of the equipment manufacturer to carry out a risk assess-

ment and to install both the detector and the equipment in compliance with 

applicable national and international regulations and safety standards, as well as 

the Machinery Directive 2006/42/EC, should this apply.

Receiver 

Tx1

Tx2

Before commencing the installation or assembly complete the following safety 

precautions:

•  Check the voltage data on the label of the switching device.

•  Ensure that the device/installations can not be switched on.

•  Determine that the power supply is disconnected.

•  Protect the device with a housing against contamination or aggressive 

environments.

•  Connect all operating and switching voltages to the same fuse. 

•  Connect the operating voltage to the same circuit as the industrial door controller. 

•  Disconnect device from mains in the event of a fault.

This equipment is not suitable for use in locations where children are likely to be 

present.

Limited protection against accidental contact!

Receiver

Output 

1

Transmitter Tx1

 (input 1) corresponds to receiver output 

Transmitter Tx2 

(input 1) corresponds to receiver output 

Further transmitters with separate manuals

Battery  

CR2450N

Push button

DIP-

Switch

Space 

to open cover

Space 

to open cover

LED SYS

DIP-switch

2

Common application

Push button

Содержание XRF-1

Страница 1: ...east once per cycle It is the responsibility of the equipment manufacturer to carry out a risk assess ment and to install both the detector and the equipment in compliance with applicable national and international regulations and safety standards as well as the Machinery Directive 2006 42 EC should this apply Receiver Tx1 Tx2 Before commencing the installation or assembly complete the following s...

Страница 2: ...Punch hole into the grommet Insert cable or use holes in the base plate Break out Hint 3 Installation DIP switch test input 1 ON Low active 1 ON High active factory setting VIN Test 4 2 Receiver Output Power supply 12 36 V ACDC 4 1 Transmitter example details see supplementary sheet of transmitter 4 Wiring Battery CR2450N DIP switch setting according to sensor safety edge switch contact Insert bat...

Страница 3: ...ed orange Wicket door open XRF TW closed open red orange Configuration Pairing closed open orange orange upon action Configuration memory full closed open orange orange 10x Low battery 8k2 closed green green 3x every min Test input active closed open red green Error Tx lost broken cable empty battery system error closed open red red flashing 8 1 Warning indicator for low battery voltage To find ou...

Страница 4: ...g and recycling of electrical and electronic equipment 9 Technical data Receiver Supply voltage 12 36 V ACDC Power consumption 0 6 W 12 V 0 7 W 36 V Safety outputs 2 relays max 36 V max 1 A max 36 W 36 VA Test input 12 36 V ACDC Sensor memory 7 Transmitter See separate manual Battery 1x Lithium 3 V CR2450N Battery life Typ 1 2 years System Operating frequency 868 3 MHz Reaction time Typ 15 ms Rang...

Отзывы: