- 133 -
Copyright © 2020 LG Electronics Inc.
All rights reserved. Only training and service purposes.
Self-diagnosis function
60
Inv. PCB EEPROM
error
Error No.
Error Type
Error Point
Main Reasons
EEPROM Access error
and Check SUM error
1. EEPROM contact defect/wrong insertion
2. Different EEPROM Version
3. ODU Inv. PCB assembly damage
n
Error Diagnosis and Countermeasure Flow Chart
Is EEPROM insertion normal?
No
Yes
Recheck power and installation condition
1. Check EEPROM insert direction/connection condition
2. Check EEPROM Check SUM
→
Replace if abnormality found
Is Inv. PCB normal?
No
Yes
Replace Inv. PCB
* Inv. EEPROM inserting point
* Right inserting direction of Inv. EEPROM
j
Note : Replace after power off