Troubleshooting Guide
- 133 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Is temperature sensor
inserted to fan PCB?
’
Check connection of heat sink
temperature connector
No
Yes
Is temperature sensor
attached to heat sink?
’
Check connection condition of
heat sink and temperature sensor
No
Yes
Is fan PCB assembly normal?
’
Replace fan PCB assembly
Recheck power and installation
condition
No
Yes
Is termperature
sensor normal?
’
No
Yes
Check heat sink temperature
sensor wire disconnection
➔
Measure temperature sensor
resistance(10k
Ω
±
5% at 77
°
F)
➔
Replace the sensor if
abnormality found
Checking temperature sensor disconnection
Fan heat sink connection
Check connection condition
1. Heatsink temperature sensor defect
2. Fan PCB assembly defect
1. Heatsink temperature sensor
defect(Open/Short)
2. Wrong connection of temperature sen-
sor connector
3. Fan PCB assembly defect
Error No.
Error Type
Error Point
Main Reasons
Heat sink temperature is over
95°C
Heatsink temperature sensor
abnormal
Fan PCB heatsink
temperature high
Fan PCB heatsink
temperature sensor
error
193*
Master 11
→
931
Slave 12
→
932
194*
Master 11
→
941
Slave 12
→
942
■
Error diagnosis and countermeasure flow chart