Troubleshooting Guide
- 127 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Overload operation (Pipe clogging/Covering/EEV
defect/Ref. overcharge
2. ODU fan motor assemble condition abnormal
(Coil disconnection/Short/Insulation damage)
3. Fan PCB heatsink assemble condition abnormal
4. Fan PCB assembly defect
Error No.
Error Type
Error Point
Main Reasons
IPM protection circuit activation
(over current / overheating)
ODU Fan PCB IPM
Fault
106*
Master
11
→
061
Slave
12
→
062
■
Error Diagnosis and Countermeasure Flow Chart
Check ODU fan motor assemble condition and locking
→
Reassemble or replace if abnormality found
1.Check fan motor U,V,W connector connection condition
→
Reassemble wire if abnormality found
2.Check fan motor wire disconnection
→
Replace ODU fan motor if abnormality found
Yes
No
Yes
No
Yes
Is fan motor assemble
condition normal?
Is fan motor wire connection
condition normal?
Is fan PCB assemble
condition normal?
No
1.Check fan PCB connector condition
→
Reassemble if abnormality found
2.Check assemble condition between fan PCB and Heatsink
→
Reassemble
heatsink if abnormality found
Yes
Is fan PCB assembly normal?
No
Fan IPM assemble position
Check assemble condition
Fan Heatsink assemble position
Check assemble condition
Hall Sensor connection
Fan Motor Wire connection
Replace fan PCB assembly
Recheck power and
installation condition
Содержание ARUN Series
Страница 134: ...P NO MFL50459503 MAY 2008 ...