Chapter 9 Patching
Page 138 Rev. 1.30.03.07.r1
Ordering of Dimmer Numbers, [S2]
You have the option of viewing and addressing dimmers either 1 - 512, per
port, or 1 - 1536 across all three ports. This soft-key toggles in between the
two views.
Sorted by Channel or Sorted by Dimmer, [S3]
This soft-key toggles between sorting either by console control channel or
by output dimmer.
Patching 1 To 1
Use the
(1 to 1)
soft-key in the Patch display to patch each channel to the
dimmer of the same number (ch 1 at dim 1, ch 2 at dim 2, etc.). This is the
default setting for the patch table. Parked dimmers, Non-Dim dimmers,
proportional dimmer levels, and profiles are retained when you execute this
command. (Refer to
Chapter 3 Setting Channel Levels
for more information
on Parked Dimmers.)
Follow these steps to create a 1 to 1 patch:
Procedure:
Notes:
1. Press
[PATCH]
Opens Patch display
2. Press
(1 to 1)
Prompt reads: "Are you sure
you want to create a 1 to 1
patch? Enter 1 = Yes, 2 = No,
3 = Select Port"
3. Enter
[1]
on Keypad
1 to 1 patch created
Selecting option 1 in the example above automatically patches all three
ports (A, B and C) to a 1 to 1 patch. This may be unwanted in some
situations; for example, when you want automated devices on Port C.
Patches for automated devices are defined from the Device
Assignments sub-display of the Setup display. See
for additional information.
Содержание 24/48
Страница 4: ...Table of Chapters Page II Rev 1 30 03 07 r1...
Страница 66: ...Chapter 4 Submasters Page 54 Rev 1 30 03 07 r1...
Страница 108: ...Chapter 5 Cues Page 96 Rev 1 30 03 07 r1...
Страница 146: ...Chapter 8 Macros Page 134 Rev 1 30 03 07 r1...
Страница 186: ...Chapter 10 Automated Devices Page 174 Rev 1 30 03 07 r1...
Страница 210: ...Chapter 12 System Settings Page 198 Rev 1 30 03 07 r1...
Страница 228: ...Chapter 14 Alternate Control Interfaces Page 216 Rev 1 30 03 07 r1...
Страница 244: ...Appendix B Specifications Page 232 Rev 1 30 03 07 r1...
Страница 248: ...Appendix C Maintenance Page 236 Rev 1 30 03 07 r1...