User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.
2. If system boots to F1 setup, update the UEFI image and reset bank to primary (if required). If the
system boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if the firmware update attempt fails, replace the system board.
•
S.51003 [S.51003]
Explanation:
An uncorrectable memory error was detected in DIMM slot % on rank %. [S.51003] An
uncorrectable memory error was detected on processor % channel %. The failing DIMM within the
channel could not be determined. [S.51003] An uncorrectable memory error has been detected. Fatal
Memory Error Occurred
Severity
Error
User Response
Complete the following steps:
1. If the compute node has recently been installed, moved, serviced, or upgraded, verify that
the DIMM is properly seated and visually verify that there is no foreign material in any DIMM
connector on that memory channel. If either of these conditions is found, correct and retry with
the same DIMM. (Note: The event Log might contain a recent 00580A4 event denoting detected
change in DIMM population that could be related to this problem.)
2. If no problem is observed on the DIMM connectors or the problem persists, replace the DIMM
identified by LightPath and/or event log entry.
3. If problem recurs on the same DIMM connector, replace the other DIMMs on the same memory
channel.
4. Check the IBM support site for an applicable service bulletin or firmware update that applies
to this memory error.
5. If problem recurs on the same DIMM connector, inspect connector for damage. If found,
replace the system board.
6. Replace the affected processor.
7.
Replace system board.
•
S.51006 [S.51006]
Explanation:
A memory mismatch has been detected. Please verify that the memory configuration is
valid. One or More Mismatched DIMMs Detected
Severity
Error
User Response
Complete the following steps:
1. Could follow an uncorrectable memory error or failed memory test. Check the log and service
that event first. DIMMs disabled by other errors or actions could cause this event.
2. Verify that the DIMMs are installed in the correct population sequence.
Appendix B. UEFI (POST) error codes
497
Содержание x3250 m6
Страница 1: ...Lenovo System x3250 M6 Installation and Service Guide Machine Types 3633 and 3943 ...
Страница 6: ...iv Lenovo System x3250 M6 Installation and Service Guide ...
Страница 18: ...4 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 60: ...46 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 100: ...86 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 516: ...502 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 678: ...664 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 685: ...Taiwan Class A compliance statement Appendix E Notices 671 ...
Страница 695: ......
Страница 696: ......