CIM Information
Prefix:
PLAT
ID:
0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
•
806f070c-2581ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (All DIMMS)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2581ffff or 0x806f070c2581ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix:
PLAT
ID:
0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology. One of the DIMMs :
•
806f070d-0400ffff : Rebuild in progress for Array in system [ComputerSystemElementName].
(Drive 0)
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
May also be shown as 806f070d0400ffff or 0x806f070d0400ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
386
Lenovo System x3250 M6 Installation and Service Guide
Содержание x3250 m6
Страница 1: ...Lenovo System x3250 M6 Installation and Service Guide Machine Types 3633 and 3943 ...
Страница 6: ...iv Lenovo System x3250 M6 Installation and Service Guide ...
Страница 18: ...4 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 60: ...46 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 100: ...86 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 516: ...502 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 678: ...664 Lenovo System x3250 M6 Installation and Service Guide ...
Страница 685: ...Taiwan Class A compliance statement Appendix E Notices 671 ...
Страница 695: ......
Страница 696: ......