IOM / ROOFTOP BALTIC Series - 0
8
03 - E Page 67
control interfaces ds50 menu tree
Main Screen
Code
Description
Code
Description
Code
Description
Code
UNIT
M
in
F
ac
to
ry
M
a
x
3-Setting
3000
1-General
3100
1-Order
31
10
1-On/Of
f
3
11
1
On/Of
f
~
Of
f
~
2-Reset Al.
3
11
2
On/Of
f
~
Of
f
~
3-Resume
3
11
3
O
n/
O
ff
~
O
ff
~
4-
Te
st
31
14
List
0
0
2
2-Clock
3120
1-Hour
3
121
h
0
~
23
2-Minute
3122
m
0
~
5
9
3-Day
3123
~
1
~
3
1
4-Month
3124
~
1
~
1
2
5-Y
ea
r
3125
~
2
~
99
2-Schedule
3200
1-T
ime
3210
1-S
tart Uno
3
2
11
h
0
2
2
2
3
2-S
tart Uno
3212
m
0
0
5
9
3-S
tart z.A
3213
h
0
6
2
3
4-S
tart z.A
3214
m
0
0
5
9
5-S
tart z.B
3215
h
0
2
2
2
3
6-S
tart z.B
3216
m
0
0
5
9
7-S
tart z.C
3217
h
0
2
2
2
3
8-S
tart z.C
3218
m
0
0
5
9
2-Anticip
ation
3220
1-Foot
3221
°C
-1
0
1
0
2
0
2-Gradient
3222
~
0
0
100
3-Control
3300
1-Customer
3310
1-S
p Room
331
1
(1)
°C
8
2
0
3
5
2-Mini.Air
3312
(1)
%
0
20
100
2-Room
3320
1-S
p Dyna
3321
(1)
°C
0
99,9
99,9
2-S
p Cool
3322
(1)
°C
8
2
1
3
5
3-S
p Heat
3323
(1)
°C
8
1
9
3
5
4-Swap Heater
3324
(1)
On/Of
f
~
Of
f
~
3-Reheat
3330
1-Activation
3331
(1)
On/Of
f
~
Of
f
~
2-
Swap Heater
3332
(1)
On/Of
f
~
Of
f
~
3340
1-S
p Dehu
3341
(1)
%
0
100
100
2-S
p Humi
3342
(1)
%
0
0
100
description
*[On / Of
f] Unit
*[Reset] Discharges the safety measures of the unit *[Override] Cancel any override action set with the DC50 *[TEST]
Test set point "LENNOX"
*[Clock] Clock setting "Hour"
*[Clock] Clock setting "Minute" *[Clock] Clock setting "Day" *[Clock] Clock setting "Month" *[Clock] Clock setting "Y
ear"
*[Zone Setting] S
tarting time "Hour" for "Unocupied" zone
*[Zone Setting] S
tarting time "Minutes" for "Unocupied" zone
*[Zone Setting] S
tarting time "Hour" for "Zone
A"
*[Zone Setting] S
tarting time "Minutes" for "Zone
A"
*[Zone Setting] S
tarting time "Hour" for "Zone B"
*[Zone Setting] S
tarting time "Minutes" for "Zone B"
*[Zone Setting] S
tarting time "Hour" for "Zone C"
*[Zone Setting] S
tarting time "Minutes" for "Zone C"
*[Anticip
ation Function] bottom of the slope in °C. Limit of
activation of the function.
This allows an anticip
ated st
artup in
the morning depending on the out
door temperature. Only for
the "Zone-A" *[Anticip
ation Function] Slope in "Minutes of anticip
ation per
degrees".This allows an anticip
ated st
artup in the morning
depending on the out
door temperature.Only for the "Zone-A"
*[Room SP] Required room temperature set point in °C.
Middle of the dead zone. [Room SP] Required room minimum fresh air rate in % Middle of the dead zone.
*[Room SP] Required value for the Dynamic Set Point.
Allows
the room set point to change according to out
door
temperature *[Room SP] Required maximum room temperature in °C. Cooling set point *[Room SP] Required minimum room temperature in °C.
Heating set point *[OFF] Heat Pump and then Heater [ON] Heater and then Heat Pump
*[F-Air Reheat]
Activate reheating of the fresh air in the dead
zone to maint
ain supply temperature.
*[F-Air Reheat] Prioritise the heating mode for fresh air reheat. [OFF] Heat Pump and then Heater [ON] Heater and then Heat Pump
*[Humidity] Desired Maximum relative humidity in Room (in %). – Dehumidification set point.
*[Humidity] Desired Minimum relative humidity in Room (in %). – Humidification set point.
ALL CODES SHOWING (1) CAN BE ADJUSTED FOR EACH TIME ZONE
Содержание Baltic BCK 020
Страница 1: ...BALTIC English August 2003 INSTALLATION OPERATING MAINTENANCE MANUAL ...
Страница 38: ...IOM ROOFTOP BALTIC Series 0803 E Page 37 VENTILaTION AIRFLOW BALANCING 020 025 Fig 37 ...
Страница 39: ...Page 38 IOM ROOFTOP BALTIC Series 0803 E VENTILaTION AIRFLOW BALANCING 035 030 Fig 38 ...
Страница 40: ...IOM ROOFTOP BALTIC Series 0803 E Page 39 VENTILaTION AIRFLOW BALANCING 045 050 040 Fig 39 ...
Страница 86: ...IOM ROOFTOP BALTIC Series 0803 E Page 85 CLIMATIC 50 CONTROLLER ELECTRICAL DATA wiring diagrams ...
Страница 87: ...Page 86 IOM ROOFTOP BALTIC Series 0803 E ELECTRICAL DATA wiring diagrams CLIMATIC 50 INPUT BCK BHK BGK BDK ...
Страница 101: ...Page 100 IOM ROOFTOP BALTIC Series 0803 E EC declaration of conformity ...
Страница 102: ...IOM ROOFTOP BALTIC Series 0803 E Page 101 EC declaration of conformity ...
Страница 103: ...Page 102 IOM ROOFTOP BALTIC Series 0803 E EC declaration of conformity ...
Страница 104: ...IOM ROOFTOP BALTIC Series 0803 E Page 103 EC declaration of conformity ...
Страница 105: ...Page 104 IOM ROOFTOP BALTIC Series 0803 E EC declaration of conformity ...
Страница 106: ...IOM ROOFTOP BALTIC Series 0803 E Page 105 EC declaration of conformity ...
Страница 108: ...IOM ROOFTOP BALTIC Series 0803 E Page 107 EC declaration of conformity ...
Страница 109: ...Page 108 IOM ROOFTOP BALTIC Series 0803 E EC declaration of conformity ...