Group 8
Job editor
Page 200
Release R1.03e
LEIBINGER JET3
8.7.3.1.11 Counter increment (methods)
With the pop-up window
<Counter Increment>
you can determine the method at
which event the counter value should be changed (incremented or decremented).
Figure 123
Counter settings (Increment methods)
with PrintGo:
The change in value of the counter happened with each the
PrintGo-signal
(even, if the print out is stopped and the printer still receives some
PrintGos from the sensor or the internal PG source).
with printing (text) end:
The change in value of the counter happens after the
print out was made.
Extern (external signal):
The change in value happens by an external signal
(interface X4).
8.7.3.2 Carry out replacements
In the functional area
<Replacements>
of the menu you can generate accordant
replacements (numbers or letters) for the counter values to get an operating specific
display or coding of the specifications.
You will find further information regarding the carrying out of
substitutions in the
chapter
Replacements
!