Group 8
Job editor
Page 174
Release R1.03e
LEIBINGER JET3
8.5.1.6 PrintGo-Gate (Print start query)
A further print start query option is available with this function. If the function is
activated the print process happens only as long as the enquired sensor is active.
The sensor which is required for the PG-gate has to be connected to the interface
X5 of the LEIBINGER JET3 also.
Example:
Endless print of tubes with interruptions between the end of the previous
tube and the beginning of the following tube.
Figure 108
Activating options:
High-Level active:
Low-Level active:
PrintGo-Gate (Print start query)
PG signals
Gate
PG signals
Gate
Signals are
disabled and not
carried out!