3.3. Environmental and Operating Conditions
Conditions
Value
Minimum storage/transit temperature
-25°C [-13°F]
Maximum storage/transit
temperature
60°C [140°F]
Minimum operating temperature
0°C [32°F]
Maximum operating temperature
50°C [122°F]
Humidity (non-condensing)
20-80% RH, non-condensing
Food/ Clean room/ Intrisic Safety (IS)
No
Dust and water
l
Dust: Affect the time between maintenance
l
Water : No
Other
l
Free from corrosive liquids or gases
l
Free from explosive liquids or gases
Table 3-1: Environmental and operating conditions of the Robotiq Palletizing Solution
Caution
Use of the Robotiq Palletizing Solution is not recommended in presence of chemicals in the environment.
AirPick Gripper Info
The input filter prevents any dust larger than 200 µm from getting inside the gripper. Dry dust will prevent the
accumulation on filters. The use of suction cups with integrated filter can be used to reduce dust accumulation.
The exhaust must not be blocked.
25