1. Place the robot on the robot base plate so its power cable is oriented towards the linear axis. Align properly with the two
dowel pins (already installed on the robot base), and secure the robot using four (4) M8 screws and Belleville washers.
The torque value required is 20 Nm.
Caution
Depending on your cobot, make sure to install screws of the right size:
l
For e-Series UR: M8 x 25 mm
l
For CB-Series UR: M8 x 22 mm
2. Unclip the mounting bracket of the cable management system that is right beside the column.
3. Press the robot power cable into the cable carrier up to the column. There are two separate raceways. You must use the
same section as the coupling cable. Push the cable into the column (via the side hole) and bring it out by the hole #1.
4. Install the cable management system ring on the B sticker present on the cable carrier (near the carriage). The robot cable
must emerge towards the top of the ring so it can be maintained (see the picture below).
5. Install the Igus R-Lock at the extremity of the cable management system before clipping the cable carrier in the bracket (on
the A sticker). It will ensure the good functionality of the cable management.
Info
Refer to the Igus triflex® R Series TRE.40B cable routing system installation instructions for more details.
33
Содержание ROBOTIQ AX Series
Страница 4: ...Palletizing Solution Instruction Manual 4...
Страница 14: ...Palletizing Solution Instruction Manual 14...
Страница 21: ...Palletizing Solution Instruction Manual 21...
Страница 82: ...6 1 2 AirPick Vacuum Gripper Fig 6 1 AirPick general dimensions 82...
Страница 83: ...Palletizing Solution Instruction Manual 6 1 3 Extra Reach Bracket 83...
Страница 84: ...6 1 4 Bracket for Two 2 Suction Cups Fig 6 2 Two air nodes bracket s dimensions 84...
Страница 110: ...1 2 2 Safety Connections Fig 12 2 Universal Robots Controller Safety Connections Schema 110...