DREXEL SLT30/35 AC CALIBRATION PROGRAMMING
5-5
Master Setup
Master Setup - This submenu contains all of the
adjustable parameters that are available in the truck
master controller.
Parameter
Units
Min
Max
Default
Description
Operating Mode
0,1,2
0
2
0
Selects 1 of 3 user
customizable operating
modes
Steer Nominal Resistance
%
0
1000
70
Sets the minimum
resistive feel for the
steering wheel
Steer Max Resistance
%
0
1000
500
Setrs the maximum
resistive feel for the
steering wheel
Steer Ratio A
%
0
1000
300
Sets the resolution of
the steering wheel at
low speeds
Steer Ratio B
%
0
1000
200
Sets the resolution of
the steering wheel at
high speeds
Lift Lockout %
%
0
30
25
Sets the BDI % for the
truck to go into lift
lockout mode
Seat Timer
.1 Sec
0
30
30
Sets the time delay that
is allowed before the
seat switch is
considered interrupted
Steer Wheel Offset
Deg
100
Sets the offset for the
steer wheel sensor
WGU Installed
On/Off
0
1
0
Set to 1 when truck is
equipped with WGU
system
Auxillary Function Installed On/Off
0
1
0
Set to 1 when truck is
equipped with auxiliary
hydraulic function
Next Service Due
Hrs
0
max hrs
0
Sets the truck hours for
when the next truck
service is due
RESTORE FACTORY
DEFAULTS
Set to 1 to restore truck
default values
STORE CHANGES
Set to 1 to store
changes made to any
Master Setup
parameters
https://www.forkliftpdfmanuals.com/
Содержание Drexel SLT30 AC
Страница 2: ...https www forkliftpdfmanuals com...
Страница 36: ...2 16 F 459 R1 TIRES BRAKES AND DRIVETRAIN Table provided for general use NOTES https www forkliftpdfmanuals com...
Страница 69: ...DREXEL SLT30 35 AC CALIBRATION PROGRAMMING 5 17 https www forkliftpdfmanuals com...
Страница 70: ...5 18 F 459 R1 DREXEL SLT30 35 AC CALIBRATION PROGRAMMING https www forkliftpdfmanuals com...