![Kyocera Mita KM-1505 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/kyocera-mita/km-1505/km-1505_service-manual_2017036087.webp)
2BT
1-5-17
(17) Image is out of
focus.
Causes
1. Defective image scanning unit.
Causes
Check procedures/corrective measures
1. Defective image scanning unit.
Replace the image scanning unit (see page 1-6-20).
(15) Image is partly miss-
ing.
Causes
1. Paper damp.
2. Paper creased.
3. Drum condensation.
4. Flawed drum.
Causes
Check procedures/corrective measures
1. Paper damp.
Check the paper storage conditions.
2. Paper creased.
Replace the paper.
3. Drum condensation.
Clean the drum.
4. Flawed drum.
Replace the drum (see page 1-6-29).
(16) Fixing is poor.
Causes
1. Wrong paper.
2. Defective pressure springs.
3. Flawed press roller.
Causes
Check procedures/corrective measures
1. Wrong paper.
Check if the paper meets specifications.
2. Defective pressure springs.
Replace the pressure springs.
3. Flawed press roller.
Replace the press roller (see page 1-6-38).