![Kyocera Mita KM-1505 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/kyocera-mita/km-1505/km-1505_service-manual_2017036034.webp)
2BT
1-4-3
Section
Item
Maintenance item contents
Initial
No.
setting*
U156 Changing the toner control level
• Toner feed start level
113
• Toner empty level
44
U157 Checking/clearing the developing drive time
—
U158 Checking/clearing the developing count
—
U161 Setting the fixing control temperature
• Primary stabilization fixing temperature
125
• Secondary stabilization fixing temperature
180
U162 Stabilizing fixing forcibly
—
U163 Resetting the fixing problem data
—
U170 Setting the drum cleaning mode
Off
U196 Turning the fixing heater on
—
U199 Checking the fixing temperature
—
U200 Turning all LEDs on
—
U207 Checking the operation panel keys
—
U208 Setting the paper size
8
1
/
2
"
×
11"
U252 Setting the destination
Inch
U254 Turning auto start function on/off
On
U255 Setting auto clear time
90
U256 Turning auto preheat/energy saver function on/off
On
U258 Switching copy operation at toner empty detection
Single mode,
70
U260 Changing the copy count timing
After ejection
U332 Setting the size conversion factor
—
U348 Setting the copy density adjustment range
Normal
U402 Adjusting margins for printing
—
U403 Adjusting margins for scanning an original on the contact glass
—
U901 Checking/clearing copy counts by paper feed locations
—
U903 Checking/clearing the paper jam counts
—
U904 Checking/clearing the service call counts
—
U910 Clearing the black ratio data
—
U917 Setting the reading/writing of backup data
Read
U990 Checking/clearing the time for the exposure lamp to light
—
U993 Outputting a VTC-PG pattern
—
U998 Outputting the memory list
—
* Initial setting for executing maintenance item U020
Developing
Fixing and
cleaning
Operation
panel and
support
equipment
Mode setting
Image
processing
Others