2BT
1-6-15
(2-2) Fitting the scanner wires
Caution:
When fitting the wires, be sure to use those specified below.
Machine front: P/N 2A11208 (gray)
Machine rear: P/N 2A11209 (black)
Fitting requires the following tools:
Two frame securing tools (P/N 2A168080)
Procedure
1. Remove the two screws holding the motor
retainer grounding plate and then the plate.
Remove the four screws holding the scanner
motor unit and then the unit.
Figure 1-6-23
2. Remove the screw and the gear.
Figure 1-6-24
3. Remove the each E ring and bushing from
the front and rear of the scanner wire drum
shaft and then remove the scanner wire drum
shaft from the scanner unit.
Figure 1-6-25
Scanner motor unit
Motor retainer grounding plate
Gear
Bushing
Bushing
E ring
E ring
Scanner wire drum shaft