![Kyocera Mita KM-1505 Скачать руководство пользователя страница 127](http://html1.mh-extra.com/html/kyocera-mita/km-1505/km-1505_service-manual_2017036127.webp)
2BT
1-6-35
(3) Detaching and refitting the fixing heater
Follow the procedure below to replace the fixing heater.
Procedure
1. Remove the fixing unit (see page 1-6-34).
2. Remove the screw holding the fixing unit front
cover and then the cover.
Figure 1-6-57
3. Remove the two screws and detach the fixing
heater wire from the fixing thrmostat.
Figure 1-6-58
4. Remove the screw holding the fixing heater
front retainer and then the retainer.
Figure 1-6-59
Fixing unit front cover
Fixing heater wire
Fixing heater wire
Nuts
Fixing heater front retainer