![Kyocera Mita KM-1505 Скачать руководство пользователя страница 118](http://html1.mh-extra.com/html/kyocera-mita/km-1505/km-1505_service-manual_2017036118.webp)
2BT
1-6-26
(10) Adjusting the margins for scanning an original on the contact glass
Perform the following adjustment if the margins are not correct.
U402
(P. 1-6-10)
U403
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Scanner leading edge margin (3
±
2.5 mm)
Scanner
left margin
(3
±
2.5 mm)
Scanner
right margin
(3
±
2.5 mm)
Ejection direction
(reference)
Scanner trailing edge margin
(3
±
2.5 mm)
Change the setting.
Increasing the value using the zoom
(+) key makes the margin wider.
Decreasing the value using the
zoom (–) key makes the margin
narrower.
Yes
No
Start
Enter maintenance mode.
Enter “403” using the copy exposure
adjustment keys or zoom +/- keys.
Press the start key.
Exp. 1(lit): Scanner left margin
Exp. 3(lit): Scanner leading edge
margin
Exp. 5(lit): Scanner right margin
Exp. 1(flashing): Scanner trailing
edge margin
Place an original and press
the start key to make a test copy.
Press the start key.
The new setting
is stored.
Setting range (initial setting/change in value per step)
Scanner left margin: 0 – +10 (2.0/0.1 mm)
Scanner leading edge margin: 0 – +10 (3.0/0.1 mm)
Scanner right margin: 0 – +10 (2.0/0.1 mm)
Scanner trailing edge margin: 0 – +10 (2.0/0.1 mm)
Select the item to be adjusted using
the copy exposure adjustment keys.
Are the margins correct?
Press the size select key and the
machine enters the test copy mode.
Yes
No
Proceed to another mode?
End
Press the stop/reset key to
exit maintenance mode.
Figure 1-6-43