2BT
2-3-6
Terminals (CN)
Voltage
Remarks
1-1
1-3
24 V DC SF
24 V DC supply from PSPCB, input (when SSW is on)
1-2
1-4
24 V DC
24 V DC supply from PSPCB, input
1-7
1-5
5.1 V DC
5.1 V DC supply from PSPCB, input
1-8
1-6
12 V DC
12 V DC supply from PSPCB, input
1-9
1-5
0/5 V DC
FH on/off, output
1-10
1-5
0/5 V DC (pulse)
Zero-cross signal, input
2-2
1-6
0 - 14 V DC
TNS control voltage, output
2-3
3-2
24 V DC
24 V DC supply for TNS, output
2-4
1-6
0 - 5 V DC
TNS detection voltage, input
2-6
3-2
24/0 V DC
TFM drive control signal (+), output
2-7
3-2
0/24 V DC
TFM drive control signal (–), output
3-1
3-2
24 V DC SF
24 V DC supply for PM, output
3-3
3-2
24/0 V DC
PM on/off, output
3-4
3-10
0/5 V DC
MSYNC signal, output
3-5
3-10
0/5 V DC (pulse)
PM drive clock pulse, output
3-6
3-2
24/0 V DC
CL on/off, output
3-7
3-2
24 V DC
24 V DC supply for CL, output
3-8
3-2
24/0 V DC
MSW on/off, input
3-9
3-2
24 V DC
24 V DC supply for MSW, output
3-11
3-10
0/5 V DC
DDSW on/off, input
3-13
3-12
0/5 V DC
RSW on/off, input
3-14
3-12
5 V DC
5 V DC supply for RSW, output
4-1
4-18
0/5 V DC
OPCB SEG0 signal, output
4-2
4-18
0/5 V DC
OPCB SEG1 signal, output
4-3
4-18
0/5 V DC
OPCB SEG2 signal, output
4-4
4-18
0/5 V DC
OPCB SEG3 signal, output
4-5
4-18
0/5 V DC
OPCB SEG4 signal, output
4-6
4-18
0/5 V DC
OPCB SEG5 signal, output
4-7
4-18
0/5 V DC (pulse)
OPCB DIG0 signal, output
4-8
4-18
0/5 V DC (pulse)
OPCB DIG1 signal, output
4-9
4-18
0/5 V DC (pulse)
OPCB DIG2 signal, output
4-10
4-18
0/5 V DC (pulse)
OPCB DIG3 signal, output
4-11
4-18
0/5 V DC (pulse)
OPCB DIG4 signal, output
4-12
4-18
0/5 V DC (pulse)
OPCB DIG5 signal, output
4-13
4-18
0/5 V DC (pulse)
OPCB DIG6 signal, output
4-14
4-18
0/5 V DC (pulse)
OPCB DIG7 signal, output
4-15
4-18
0/5 V DC
OPCB KEY0 signal, input
4-16
4-18
0/5 V DC
OPCB KEY1 signal, input
6-1
6-14
24/0 V DC
BYPPFCL on/off, output
6-2
6-14
24 V DC
24 V DC supply for BYPPFCL, output
6-3
6-14
24 V DC
24 V DC supply for PFCL, output
6-4
6-14
24/0 V DC
PFCL on/off, output
6-5
6-14
24 V DC
24 V DC supply for RCL, output
6-6
6-14
24/0 V DC
RCL on/off, output
6-7
1-6
0 - 5 V DC
Transfer charging control voltage, output
6-8
6-14
0/5 V DC
Transfer charging on/off, output
6-9
1-6
0 - 5 V DC
Developing bias control voltage, output
6-10
6-14
0/5 V DC
Developing bias on/off, output
6-11
6-14
0/5 V DC
Main charging ALM signal, input
6-12
1-6
0 - 5 V DC
GRID control voltage, output
6-13
6-14
0/5 V DC
Main charging on/off, output
6-15
6-14
24 V DC SF
24 V DC supply for HVTPCB, output
9-1
1-6
–
ETTH detection voltage, input
9-3
1-6
0 - 5 V DC
HUMSENS detection voltage, input
9-4
9-2
5 V DC
5 V DC supply for HUMSPCB, output
11-2
11-1
0/5 V DC
SHPSW on/off, input