![Kyocera Mita KM-1505 Скачать руководство пользователя страница 112](http://html1.mh-extra.com/html/kyocera-mita/km-1505/km-1505_service-manual_2017036112.webp)
2BT
1-6-20
(4) Detaching and refitting the ISU (reference)
Take the following procedure when the ISU is to be checked or replaced.
Procedure
1. Remove the printer cover, right cover and
contact glass.
2. Remove the rear cover and the shield cover.
3. Detaach connectors CN16 and CN17 on the
main PCB.
Figure 1-6-34
4. Remove the ISU cable plate.
5. Remove the four screws holding the ISU
cover and then the cover.
Figure 1-6-35
6. Remove the four screws holding the ISU and
then the ISU.
7. Replace the ISU and refit all the removed
parts.
8. Run maintenance items U065, U066 and
U067 to adjust the copy image.
Figure 1-6-36
CN16
CN17
ISU cable plate
ISU cover
ISU