2BT
1-5-9
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Main charger problem
• MC ALM signal is detected
continuously for 800 ms when MC
REM signal is turned on.
Broken fixing heater wire
• It takes 15 s or more for the fixing
temperature to reach 50
°
C/122
°
F
after the power is turned on or the
safety switch is turned off and on.
• It takes 10 s or more for the fixing
temperature to reach 100
°
C/212
°
F
from 50
°
C/122
°
F.
• It takes 24 s or more for the fixing
temperature to reach the secondary
stabilization fixing temperature from
the primary stabilization fixing
temperature.
Abnormally low fixing unit
thermistor temperature
• The fixing temperature remains below
90
°
C/194
°
F for 10 s during copying.
Abnormally high fixing unit
thermistor temperature
• The fixing temperature exceeds
230
°
C/446
°
F for 10 s.
Deformed high-
voltage
transformer PCB
terminal spring.
Fixing heater
installed
incorrectly.
Broken fixing
heater wire.
Poor contact in
the fixing unit
thermistor
connector
terminals.
Broken fixing unit
thermistor wire.
Fixing unit
thermistor
installed
incorrectly.
Fixing unit
thermostat
triggered.
Fixing heater
installed
incorrectly.
Broken fixing
heater wire.
Poor contact in
the fixing unit
thermistor
connector
terminals.
Broken fixing unit
thermistor wire.
Fixing unit
thermistor
installed
incorrectly.
Fixing unit
thermostat
triggered.
Shorted fixing unit
thermistor.
Broken fixing
heater control
circuit on the
power source
PCB.
Replace the spring.
Check and reinstall if necessary.
Check for continuity. If none, replace fixing
heater.
Check the connection of connector CN11
on the main PCB and the continuity across
the connector terminals. Remedy or
replace if necessary.
Measure the resistance. If it is
∞ Ω
, replace
the fixing unit thermistor.
Check and reinstall if necessary.
Check for continuity. If none, replace the
fixing unit thermostat.
Check and reinstall if necessary.
Check for continuity. If none, replace fixing
heater.
Check the connection of connector CN11
on the main PCB and the continuity across
the connector terminals. Remedy or
replace if necessary.
Measure the resistance. If it is
∞
Ω
, replace
the fixing unit thermistor.
Check and reinstall if necessary.
Check for continuity. If none, replace the
fixing unit thermostat.
Measure the resistance. If it is
0
Ω
, replace
the fixing unit thermistor.
Replace the power source PCB.
A510
(C510)
C610
C620
C630