3.0 Teach-In Setup-1
After the SIL 3 shaft copying system has been
recognized, the Setup 1 parameter is dis-
played in the Status Safe parameter. By press-
ing the Enter key one enters the input routine.
3.1 Enter the zone length
This parameter is used to enter the zone length. Later, the zone length can be
shortened, but not increased!
Change value and enter default value of 200
mm.
The entry is completed with the
ENTER key
.
When the value is accepted, the
saved mes-
sage appears.
3.2 Entering the inspection limit switch (protection mode)
With shortened pit or / and shortened pit head, inspection switches can be set. The dis-
tance to the upper or lower limit switch is 1.2m. These positions are fixed. In order to make
it possible to leave the shaft head / pit, the car is already stopped at a distance of 1.4 m!
Shaft pit and pit brow have normal height.
attitude -> No limit switch
and confirm with
enter.
Shaft pit have reduced depth.
attitude -> Limit switch down
and confirm
with enter.
Pit brow have recuced height.
attitude -> Limit switch up
and confirm with
enter.
Shaft pit and pit brow are reduced.
attitude -> Limit switch up+down
and con-
firm with enter.
After confirmation with ENTER the
saved
message appears.
3.3 Enter the nominal speed
The SIL-3 shaft copying system can detect overspeed at 115% of nominal speed.
For this, the nominal speed must be entered.
The default value is
5,00 m/s
. This value
must be adjusted on the
nominal speed of
the elevator system
.
The entry is completed with the
ENTER-Key
.
When the value ist accepted, the
saved mes-