![KW DAVID-613 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/kw/david-613/david-613_manual_2013611006.webp)
KW Aufzugstechnik GmbH Inbetriebnahme DAVID-613
DAVID-D613-Inbetriebnahme-V124-EE 18.02.2022 Seite - 6 -
1A
Mounting of the Switching Cabinet – Example KW04M
The control cabinets KW01 and KW04 are intended for mounting on the wall.
If a switch cabinet socket is provided, the control cabinet is installed
with the Step 6.
Back to wall mounting: The control cabinets KW01 and KW04 have a guide groove
At the bottom of the bottom -> see picture Step 3. First, two screws are fixed in the wall,
whereupon the cabinet can be placed so that the top fixing holes can be marked and
drilled ...
Ensure that the fans are able to dissipate the heat to the right and left unhindered.
2A
Assembly oft he Mounting Screws
As a first step, the two lower fixing holes are drilled into the masonry. First make sure that
the masonry has the necessary load bearing capacity. Otherwise, the use of a base is
recommended.
2 screws M8 with universal universal lever are used. The drilling distances are:
Distance of the drill holes in the cabinet KW04M: 490mm
Distance of drill holes in cabinet KW01N: 685mm
3A
Positioning the Switching Cabinet in order to markt he As-
sembly-Holes above
Do not screw the screws completely into the wall so that the cabinet with its guide groove
can be placed on it and snapped into place.
Secure the cabinet with one hand against the drifting and mark the upper holes.
Now the cabinet can be safely placed on the floor again.
4A
Making the Assembly-Drills above
Like the two lower ones, the two upper fixing holes are now drilled into the masonry.
To use are again 2 pieces of 10 universal blinds.
5A
Final-Mounting - Mounting of the Switching Cabinet
Now the cabinet can be parked on its guide groove and click into place. The above
screws can be screwed in with a wrench or the ratchet.
Then the lower screws are tightened with a wrench.
If necessary (obstruction of the escape route) change the door stop.
For installations with a machine room, the cable duct is now installed.
6A
Optional – Usage of a Socket of a Switch-
ing Cabinet
The KW06 and KW07 cabinets are supplied with a base as standard.
Optional sockets are available for cabinets KW03, KW04, KW240.
Before assembling the base, please make sure you know how to feed
the cables and make the corresponding cutouts!
The strain relief of the cables takes place in the base.