13
. The belt breaker 8 is operated by the groove in the lower belt
holder 3. Please fasten the belt breaker on the shaft lug holder.
The shaft flag holder with the belt breaker is now positioned so that a
mark on the belt clip is visible upwards and one downwards. The
shaft flag holder is to be tightened at a
90 degree angle
with a tight-
ening torque of 20 Nm.
14
.Subsequently, the
band breaker 8 is set
sharp. To do this, care-
fully remove the plunger
(actuator) with a screw-
driver
Electrical Connection:
15.
In the shaft pit / shaft pit box: In-
serting the belt breaker cable with
the
wires 1-> 2D and 2-> 2E.
16.
On the elevator car / inspection box:
Plug in the SCA cable with the
715-PE-716
plug
and the
2Z-3 plug.
17.
In the inspection
box: Plug in the
POI
cable
with the pre-
extended plug.
Attention!
18. Ground the sensor with the grounding cable provided by mounting the sensor
with the flat plug and the other end in the inspection box on PE!
Control & Care:
19
. Clean the tape after installation. Use a dry, clean cloth. Start at the head of the shaft and
take the inspection trip all the way down. Pull the tape gently through the cloth. Avoid the
penetration of foreign bodies into the sensor slot!
20.
Check the correct installation. Deviations and angular misalignment must be corrected.
An inspection trip through the shaft is the best way to do this.