KW Aufzugstechnik GmbH Inbetriebnahme DAVID-613
DAVID-D613-Inbetriebnahme-V124-EE 18.02.2022 Seite - 42 -
70
Principle picture -
connection cabin
There are 3 brewing groups in the inspection box for con-
necting devices, namely the
FKR
(right), the
X11
(bottom
left) and the
X11-XPU
(top left).
Mounting steps on the cabin
Step Activity
71
Mounting the inspection box
72
Mounting the suspension cable
73
Hanging wire connection
74
Connection catch contact
75
Connection slack rope contact 1
76
Connection slack rope contact 2
77
Hatch position contact connection
78
Connection limit switch (Hyd 2:1)
79
Connection of inspection limit switch.
80
Connection folding railing switch. 1
81
Connection folding railing switch. 2
82
Connection folding railing signal. +24V
83
Connection shelter light H22
84
Connection car door contacts
85
Connecting the cabin light
86
Connection of the cabin fan
87
230V load measurement/light grid con-
nection
88
Connection 230V door operator(s)
89
Connection Door commands Door op-
erator(s)
90
Connection CANopen door operator(s)
91
Connection 400V AC door operator(s)
92
Connection light grid door-1 ... Door-3
93
Audio-visual alarm connection H69
94
Door limit switch connection, reversing.
95
Connection latch solenoid(s)
96
Connection cabin gong loudspeaker
97
Connection KW load sensor
98
Connection overload, full load and un-
derload
99
Connection CANopen load measure-
ment
100
Connecting the interior panels
101
Connection KW TFT displays
102
Connection KW Matrix displays
103
Connection CANopen display
104
Connecting the push-buttons to the EIT
105a Mounting ELGO LIMAX-SAFE-CP33
106b Mounting Kübler LES02-SAFE
105a Commissioning ELGO LIMAX-SAFE
106b Commissioning Kübler LES02-SAFE
71
Mounting the inspection box
The inspection box has 4 mounting holes with which it is attached
to the railing on the cabin roof.
The hole size is 356 x 295 mm (W x D).
It is best to use M6
threaded screws with locking washers as screws.
All cables are fed in from below. from below. The cables are
strain-relieved with the enclosed cable ties in the preparatory fas-
tening eyelets.
The suspension cable is fastened with the enclosed special sus-
pension cable holder.