KW Aufzugstechnik GmbH Inbetriebnahme DAVID-613
DAVID-D613-Inbetriebnahme-V124-EE 18.02.2022 Seite - 48 -
103
Connection display - panel via CANOpen on the
cabin
When using CANOpen displays, such as BS Tableau, the enclosed CANbus cable is
used.
This is plugged into the lower CANbus terminal on the X11-XPU module in a de-energised
state.
Further CANbus devices are extended with further CANbus cables on the preceding line.
The last device is provided with a terminating resistor. The CANOpen display represents a
CANbus account to which the buttons of the interior panel can be connected.