![KW DAVID-613 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/kw/david-613/david-613_manual_2013611060.webp)
KW Aufzugstechnik GmbH Inbetriebnahme DAVID-613
DAVID-D613-Inbetriebnahme-V124-EE 18.02.2022 Seite - 60 -
ODER
Therefore, the lowest floor will start manually
(
INSPECTION OR RETURN CONTROL
)
Now press the
red "UP" button in the HPG
or
press the
QUICK button
on the inspection bulb
Sequence:
! The piezo will sound in the cabin
for 1 second and the text "Floor stored" will be
displayed as confirmation in the 3rd line
Learn next floor by
:
Pressing the UP-button on the inspection bulb
or if the HPG-60 is being used, press the
ENTER button. The 3
rd
line is activated: Dis-
play 3
rd
line: “Input: UP button”.
1.) The floor-02 with start inspection (or return).
2.) Press the QUICK button on the inspection
bulb,
or
press the UP button if the HPG-60 is
being used.
Note: If the penultimate floor is reached, then the top floor is automatically occupied (limit switch
TOP:-100mm)
Result:
The piezo sounds in the cabin for 1 second and in the 3
rd
line the text “
Floor saved”
is
displayed as confirmation
Now switch the elevator to normal opera-
tion
Go to STEP 3.10