9. Maintenance
9
Maintenance
9.1
Maintenance table
Maintenance table
Fig. 9-1: Maintenance points
Item
Activity
Time re-
quired [min]
Maintenance interval
1
Clean fan for inner
cooling circuit with
brush.
15
Depends on installation
conditions and degree of
fouling; however, no later
than every 2 years
Clean fan for outer
cooling circuit with
brush.
15
2
Clean heat ex-
changer with
brush.
15
Clean heat sink
with brush and
check that it is se-
curely fastened.
15
1
Exchange fan for
inner cooling cir-
cuit.
(
>>>
ging the internal
fan" page 90)
20
5 years (with 3-shift op-
eration)
Exchange fan for
outer cooling cir-
cuit.
(
>>>
ging the external
fan" page 91)
20