19
Malfunction, cause and remedy
19.5
Faults of the electrics/electronics
250
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
Possible cause
Remedy
The wiring of the sensor is de-
fective.
Check sensor and wiring for damage,
.
522110-
B10
R
Sensor B10 “Filling display right”
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
522111-
B11
L
Sensor B11 “Lock hook bale chamber left”
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
522112-
B12
R
Sensor B12 "Lock hook bale chamber right"
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.
522115-
B15
Sensor B15 "Bale ejection"
For version with "TIM"
Possible cause
Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage,
.
The wiring of the sensor is de-
fective.