Malfunction, cause and remedy
19
Faults of the electrics/electronics
19.5
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
229
19.5.2
Overview of fuses
The circuit board with the fuses is located on the right side of the machine behind the side hood.
As indicated on the circuit diagram, the following fuses are on the circuit board:
RPG000-080
Designa-
tion
Explanation
Designa-
tion
Explanation
A1.F1
Reserve
A1.F7
PWR plug X551
A1.F2
KMC A10 PWR UB1
A1.F8
KMB A30 / A31 PWR UB
A1.F3
KMC A10 PWR UB2
A1.F9
KMC A10 ECU_PWR
A1.F4
Reserve
A1.F10
ISOBUS expansion ECU PWR
A1.F5
ISOBUS expansion PWR
A1.F11
ECU plug X551
A1.F6
Reserve
19.5.3
Remedying sensor/actuator error
Components must be repaired or replaced by a qualified specialist workshop only.
Before contacting the dealer, collect the following information about the error message:
Note the error number and the respective FMI (
display.
Shut down and safeguard the machine,
Check sensor/actuator externally for damage.
Æ
If the sensor/actuator is damaged, replace the sensor/actuator.
Æ
If the sensor/actuator is not damaged, continue with the next test step.
Check connector cable and plug connection for damage and tightness.
Æ
If the connector cable/plug connection is damaged, replace the connector cable/plug
connection.
Æ
If the sensor/actuator is not damaged, continue with the next test step.
Perform an actuator test in case of an actuator error to identify the actuator status,
.
If a sensor is defective, run a sensor test to identify the sensor status,
The more information the dealer has, the easier it is to eliminate the cause of the error.
19.5.4
Error list
General aspects on error causes