18
Maintenance
18.26 Servicing compressed air brake (for version with "Compressed air brake")
220
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
NOTICE
Damage to compressed air reservoir caused by water in the compressor unit
Water in the compressor unit leads to corrosion which damages the compressed air reservoir.
Check and clean drain valve according to maintenance table,
.
Immediately replace a defective drain valve.
DVG000-014
The compressed-air reservoir stores the compressed air that is pumped by the compressor.
Condensation water may settle in the compressed air reservoir (1) during operation. The
compressed-air reservoir (1) must be emptied regularly,
The drain valve (2) is on the underside of the compressed air reservoir (1).
Shut down and safeguard the machine,
WARNING! Risk of eye injury due to spurting condensation water! Wear suitable
protective goggles.
ü
A suitable container is available for escaping condensation water.
Open the drain valve (2).
Æ
Allow compressed air and condensation water to escape out of the compressed-air tank (1).
Visually inspect the drain valve (2) to ensure that it is not defective or soiled.
Æ
If the drain valve (2) is defective and is no longer sealed, immediately have the drain
valve (2) replaced by a KRONE service partner.
Æ
If the drain valve (2) is soiled, clean the drain valve (2).
18.26.3
Retighten tensioning straps at the compressed air tank
For an overview of the tightening torques,
.