Settings
17
Locking/releasing the tension lever
17.9
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
179
17.9
Locking/releasing the tension lever
For the "Net and chamber film wrapping" version
3
3
I
II
4
4
2
1
RP000-187
Position (I) (net wrapping)
The locking pin with ball head (3) is released (shown with a red border in the figure). The
tension lever (2) is positioned on the net roll (1).
Position (II) (chamber film wrapping)
The locking pin with ball head (3) is locked in the side wall (shown with a red border in the
figure). This keeps the tension lever (2) in bottom position to prevent it from touching the film
roll (1).
Setting the chamber film wrapping (from position (I) to position (II))
To lock the locking pin with ball head (3), turn the ball head clockwise until the roll pin (4)
moves through the slot.
At the same time, move the tension lever (2) downwards to the borehole.
Æ
The compression spring automatically presses the bolt into the borehole.
Setting the net wrapping (from position (II) to position (I))
To release the locking pin with ball head (3), turn the ball head anti-clockwise and pull the
bolt in the direction of the arrow until the roll pin (4) moves through the slot and the bolt has
engaged.