Malfunction, cause and remedy
19
Faults of the electrics/electronics
19.5
Comprima F 155 XC
Original Operating Instructions 150001050_01_en
247
522038-
Bale chamber bale formation conveyor
Possible cause
Remedy
FMI 1: The setpoint speed of the bale formation conveyor of the bale chamber was below the
minimum.
The bale formation conveyor
is rotating slower than it
should. Slippage is occurring.
Use fewer blades.
Completely switch off blades or partially remove.
Reduce the baling pressure.
Check and set the sensor B01 "Speed of bale chamber",
Check and set the sensor B05 "Slip floor conveyor",
Very heavy and/or wet crops
are being loaded.
522040-
Round bale in the bale chamber
Possible cause
Remedy
FMI 0: There is a filling problem. The round bale in the bale chamber is too small on the right
side.
The bale chamber is filled
very unevenly. More crops
were fed in on the left side
than on the right side.
Fill the bale chamber more evenly.
Drive more slowly at the end of the round bale.
Check and set the sensor B10 "Filling display right",
522041-
Round bale in the bale chamber
Possible cause
Remedy
FMI 0: There is a filling problem. The round bale in the bale chamber is too small on the left
side.
The bale chamber is filled
very unevenly. More crops
were fed in on the right side
than on the left side.
Fill the bale chamber more evenly.
Drive more slowly at the end of the round bale.
Check and set the sensor B09 "Filling display left",
522044-
Tailgate
Possible cause
Remedy
FMI 2: When moving to a position, the current position of the tailgate could not be determined.
The sensors are defective or
have been incorrectly set.
Check and set the following sensors,
:
• Sensor B11 Lock hook bale chamber left
• Sensor B12 Lock hook bale chamber right
There is a mechanical fault at
one of the sensors.
Contact the KRONE service partner.