![Krone Comprima F 125 XC-1 Скачать руководство пользователя страница 312](http://html1.mh-extra.com/html/krone/comprima-f-125-xc-1/comprima-f-125-xc-1_operating-instructions-manual_2004803312.webp)
8
Terminal error messages
8.1
Faults of the electrics/electronics
68
Comprima F 125 - 1, Comprima F 125 XC - 1, Comprima F 155 - 1, Comprima F 155 XC - 1, Comprima V 150 - 1,
Comprima V 150 XC - 1, Comprima V 180 - 1, Comprima V 180 XC - 1, Comprima V 210 XC - 1
Comfort 1.0_en
Possible cause
Remedy
FMI 4: There is a cable break/short circuit, general error or undervoltage.
The cabling is faulty.
Check the cabling for damage,
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, see appendix
“Circuit diagram”.
Check the sensor and cabling for damage,
.
The control unit KMC is de-
fective.
Replace the control unit KMC.
521102-
High
Voltage group (UB3) of the KRONE Machine Controller (KMC)
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
The cabling is faulty.
Check the cabling for damage,
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, see appendix
“Circuit diagram”.
Check the sensor and cabling for damage,
.
The control unit KMC is de-
fective.
Replace the control unit KMC.
521102-
Low
Voltage group (UB3) of the KRONE Machine Controller (KMC)
Possible cause
Remedy
FMI 6: There is a short circuit or ground fault.
The cabling is faulty.
Check the cabling for damage,
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, see appendix
“Circuit diagram”.
Check the sensor and cabling for damage,
.
The control unit KMC is de-
fective.
Replace the control unit KMC.
521103-
High
Voltage group (UB4) of the KRONE Machine Controller (KMC)
Possible cause
Remedy
FMI 3: There is a short circuit or an overvoltage.
The cabling is faulty.
Check the cabling for damage,
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, see appendix
“Circuit diagram”.
Check the sensor and cabling for damage,
.
The control unit KMC is de-
fective.
Replace the control unit KMC.
521103-
Low
Voltage group (UB4) of the KRONE Machine Controller (KMC)
Содержание Comprima F 125 XC-1
Страница 335: ...150 102 161 00 Comprima F 125 1 F 155 1 1 3 5 5 6 1 2 3 ...
Страница 337: ...150 102 161 00 Comprima F 125 XC 1 F 155 XC 1 2 3 1 3 5 5 A A1 P K3 K1 7 7 3 A B A A1 P K21 K20 1 ...
Страница 339: ...150 102 247 00 Comprima V 150 1 V 180 1 1 3 4 T P 50 180 bar ST A MS 1V1 S F R F R 1V1 Q30 6 5 5 3 1 T 1 2 ...
Страница 345: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ 5XQGEDOOHQSUHVVH RPSULPD 9 1 ...
Страница 373: ......