![Krone Big Pack 1270 HS Скачать руководство пользователя страница 275](http://html1.mh-extra.com/html/krone/big-pack-1270-hs/big-pack-1270-hs_original-operating-instructions_2004791275.webp)
Placing in Storage
275
Pos: 36.13 /Überschriften/Überschriften 3/U-Z/Überlastkupplung am Schwungrad @ 46\mod_1282047883734_78.doc @ 445914
14.3.1
Overload coupling on flywheel
Pos: 36.14 /BA/Einlagerung/Großpackenpresse/Überlastkupplung am Schwungrad Hinweis @ 46\mod_1282048018156_78.doc @ 445940
Note
After the machine has been idle for long periods of time, the linings of the overload coupling (1)
may adhere to friction surfaces. Vent the overload coupling before use.
Pos: 36.15 /BA/Einlagerung/Großpackenpresse/Überlastkupplung am Schwungrad BYPY 890/1270/890 (XC) @ 48\mod_1286255932953_78.doc @ 459871
Procedure for types BiG Pack 890 (XC) BiG Pack 1270 (XC) and BiG Pack 1290(XC)
Fig. 198
•
The overload coupling is on the flywheel (3)
•
To vent it, release the nuts (2) on the overload coupling (1) until the disc spring (4) is
released
•
Turn the universal shaft manually around once
•
Afterwards, retighten the nuts crosswise until the setting dimension X = 16,9 mm is set
Pos: 36.16 /BA/Einlagerung/Großpackenpresse/Überlastkupplung am Schwungrad BYPY 1290 HDP(XC) BP 12130 @ 46\mod_1282044788109_78.doc @ 445861
Procedure for types BiG Pack 1290 HDP/XC and BiG Pack 12130
Fig. 199
•
The overload coupling is located on the flywheel (3)
•
To vent it, release the nuts (2) on the overload coupling (1) until the compression springs
are released
•
Turn the universal shaft manually around once
•
Afterwards, retighten the nuts crosswise until the setting dimension X = 75.8 mm is set
(measured from the outer edge of the disc (4))
Pos: 37 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165