![Krone Big Pack 1270 HS Скачать руководство пользователя страница 143](http://html1.mh-extra.com/html/krone/big-pack-1270-hs/big-pack-1270-hs_original-operating-instructions_2004791143.webp)
KRONE ISOBUS-Terminal CCI 100
143
Pos: 24.175 /BA/Info-Center/Großpackenpresse/Hauptmenüs/Alarmmeldungen/4) Alarmmeldungen Tabelle allgemein 101-113 @ 19\mod_1238506114415_78.doc @ 220281
No. Image
Description
Possible
cause
Remedy
101
Twine monitoring
sensor
Sensor or line defective
Perform a sensor test
Check the sensor and line for
damage
-
102
Packer monitoring
sensors
103
Packer feed
sensor
104
Upper blade bar
sensor, top
105
Cutter sensor
active
106
Knotter
monitoring sensor
107
Measuring force
sensor
108
Calibration force
sensor
109
Sensor flywheel
brake
110
Needle
connecting rod
sensor
111
Bale chute sensor
112
Force sensor,
right
Sensor, measurement amplifier or
line defective
Check the sensor and line for
damage
113
Force sensor, left
Sensor, measurement amplifier or
line defective
Check the sensor and line for
damage
Pos: 24.176 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165