![Krone Big Pack 1270 HS Скачать руководство пользователя страница 139](http://html1.mh-extra.com/html/krone/big-pack-1270-hs/big-pack-1270-hs_original-operating-instructions_2004791139.webp)
KRONE ISOBUS-Terminal CCI 100
139
Pos: 24.168 /Überschriften/Überschriften 3/A-E/Alarmmeldungen @ 34\mod_1255441373066_78.doc @ 323566
7.16 Alarm
messages
Pos: 24.169 /BA/Info-Center/Großpackenpresse/Hauptmenüs/Alarmmeldungen/1) Alarmmeldungen Tabelle allgemein A01 - A17 HS Baureihe @ 64\mod_1300112639026_78.doc @ 580114
No. Screen Description
Possible
cause
Remedy
A01
Fuse 2 defective
Short circuit at the
outputs
Replace the fuse and then test all
actuators in the actuator test to
determine whether an actuator has
a short circuit.
A02
Fuse 3 defective (self-
repairing)
Short circuit in electrical
power supply for
sensors.
Check wiring to Multi-Bale
potentiometer, star wheel,
pressure sensor and force
measurement amplifier.
A03
CAN connection
between terminal and
job computer
interrupted
CAN wiring defective
Check the CAN wiring
A04
EEPROM error
Job computer defective Replace
the
job computer
A05
CAN connection
broken between job
computer and Krone
I/O computer
CAN wiring defective
Krone I/O computer
inactive
Check the CAN wiring
Check the cables.
Replace Krone I/O computer
A11
KMV1
CAN connection
broken between job
computer and Krone
measurement force
computer (KMV1)
CAN wiring defective
Krone measurement
force computer (KMV1)
inactive
Check the CAN wiring
Check the cables.
Replace Krone measurement force
computer (KMV1).
A12
KMV2
CAN connection
broken between job
computer and Krone
measurement force
computer (KMV2)
CAN wiring defective
Krone measurement
force computer (KMV2)
inactive
Check the CAN wiring
Check the cables.
Replace Krone measurement force
computer (KMV2).
A14
Undervoltage
- Tractor battery
defective
- Tractor dynamo too
weak
- 12-V power supply too
weak on the tractor side
or not correctly
connected with the
battery
Connect the KRONE connection
cable directly to the tractor battery
A15
Overvoltage
Tractor dynamo
defective
Check dynamo
A17
RMC
CAN connection
broken between job
computer and Krone
humidity measurement
computer (RMC)
CAN wiring defective
Krone humidity
measurement computer
(RMC) inactive
Check the CAN wiring
Check the cables.
Replace Krone humidity
measurement computer (RMC).
Pos: 24.170 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165