![Krone Big Pack 1270 HS Скачать руководство пользователя страница 270](http://html1.mh-extra.com/html/krone/big-pack-1270-hs/big-pack-1270-hs_original-operating-instructions_2004791270.webp)
Maintenance – lubrication
270
Pos: 34.60 /Überschriften/Überschriften 3/A-E/Einstellung der Sensoren @ 0\mod_1199962173428_78.doc @ 37635
13.8.1
Adjusting the Sensors
Pos: 34.61 /BA/Wartung/Sensoren/Namursensor d = 08 mm @ 24\mod_1241770312369_78.doc @ 248607
13.8.1.1 Namur sensor d = 8 mm
a
BP-VFS-088-1
2
1
3
Figure 195:
The dimension between the encoder (2) and the sensor (1) must be "a" = 0,5 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 0,5 mm
is reached.
•
Tighten the nuts again.
Pos: 34.62 /BA/Wartung/Sensoren/Namursensor d = 12 mm @ 0\mod_1199962247038_78.doc @ 37654
13.8.1.2
Namur sensor d = 12 mm
a
BP-VFS-088-1
2
1
3
Figure 196
The dimension between the encoder (2) and the sensor (1) must be "a" = 2 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension "a" = 2 mm
is reached.
•
Tighten the nuts again.
Pos: 34.63 /BA/Wartung/Sensoren/Namursensor d = 30 mm @ 0\mod_1199962520100_78.doc @ 37673