KRONE ISOBUS-Terminal CCI 100
123
Pos: 24.96 /BA/Info-Center/CC-ISOBUS-Terminal/CCI-BiG Pack/Hauptmenüs/Hauptmenü 4 Service/Menü 4-2 Sensortest Hand @ 44\mod_1275483833375_78.doc @ 391921
7.12.1
Menu 4-2 „Manual sensor test“
BPK40190_1
4-2
CC000040
4-2
1
B1
B2
Fig. 78
In the manual sensor test, the sensors that are installed on the machine are checked for errors.
In addition, the sensors can be correctly adjusted in the manual sensor test. There is no
guarantee the machine is working correctly until after the sensors have been adjusted.
Caution!
The P.T.O. shaft must not be turning during the sensor test.
Calling the menu
Main menu 4 "Service" is called.
•
You can select menu 4-2
by pressing function key
or
. The symbol is shown in
reverse colors
•
Press the rotary potentiometer
•
Press function key
Selecting the sensor
•
Select the sensor by pressing the function key
or
The selected sensor is displayed inversely and is tested.
Pos: 24.97 /BA/Info-Center/Schwader/Bedieneinheit - Komfort/Swadro 1400/Hauptmenüs/Hauptmenü 4 Service/Einstellwerte Sensor allgemeiner Text @ 6\mod_1215416779856_78.doc @ 101137
Setting values:
The minimum and maximum setting values with the sensor alive (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be adjusted so that in the alive state the bar is
in the upper mark. Next check whether the bar is in non-alive state in the lower marked area.
Pos: 24.98 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165