Pos: 32.62 /BA/Einstellungen/Großpackenpresse/Nadeleinstellungen/Oberer Totpunkt der Nadeln @ 21\mod_1239093619118_78.doc @ 228856
10.2.3
Top dead centre of the needles
To be able to check the upper dead point of the needles, turn the needle yoke up to its highest
position (dead centre point) (II). The needles (4) protrude out from the knotter. The distance "b"
between the upper edge of the drive disc (2) and the mid-point of the lower roll on the needle
point should be at least b = x mm with twine. If the setting is not correct, it should be corrected
by shortening or lengthening the needle connecting rod (3). The needles should not touch the
cleaners (6) of the tappet (2) in their highest position.
Pos: 32.63 /BA/Einstellungen/Großpackenpresse/Nadeleinstellungen/Oberer Totpunkt Mass b Einachknoter und Doppelknoter @ 21\mod_1239093730930_78.doc @ 228880
Single knotter: b = 120 - 130 mm
Double knotter: b = 105 - 115 mm