![Krone Big Pack 1270 HS Скачать руководство пользователя страница 247](http://html1.mh-extra.com/html/krone/big-pack-1270-hs/big-pack-1270-hs_original-operating-instructions_2004791247.webp)
Maintenance - Brake System
247
Pos: 34.43.5 /Überschriften/Überschriften 2/A-E/Druckluftbehälter @ 12\mod_1224144256075_78.doc @ 150965
12.2
Compressed-air reservoir
Pos: 34.43.6 /BA/Wartung/Druckluftbehälter/Druckluftbehälter Bild BP 890/1270/1290 HS Baureihe @ 62\mod_1299662280569_78.doc @ 574094
4
BPHS0018
2
3
1
Fig.179
Pos: 34.43.7 /BA/Wartung/Druckluftbehälter/Druckluftbehälter Text Zusatz Big Pack HS Baureihe @ 62\mod_1299662408501_78.doc @ 574121
•
Big pack square balers equipped with a compressed air brake have two compressed air
storage tank (1x compressed air storage tank (2) for the compressed air brake / 1x
compressed air storage tank (4) for knotter cleaning).
•
Big pack square balers equipped with a hydraulic brake have one compressed air storage
tank (4) (1x for knotter cleaning).
• For big pack square balers equipped with a pressurized air brake the compressed air
storage tank (2) for the brake system is on the right hand side of the machine. It is connected
with the compressed air storage tank (4) for knotter cleaning through a compressed air line (1).
The compressed air storage tank (4) for knotter cleaning (compressed air brake / hydraulic
brake) can be found on the right hand side above the twine box on the frame.
Pos: 34.43.8 /BA/Wartung/Druckluftbehälter/Druckluftbehälter_Text @ 0\mod_1200293406164_78.doc @ 39343
The compressed-air reservoir stores the compressed air that is pumped by the compressor.
Therefore condensation water may settle in the compressed air reservoir during operation. The
compressed-air reservoir must be emptied regularly. Specifically, it must be emptied:
•
daily in winter (when being used),
• otherwise weekly and
• at least after 20 operating hours.
The drain valve on the bottom of the compressed-air reservoir is used for draining.
•
Switch off and secure the machine.
•
Open the drain valve and allow the condensation to run out.
•
Check the drain valve, clean it and screw it back in.
Note
If the drain valve has a heavy accumulation of dirt or is leaking, it must be replaced by a new
one.
Pos: 34.43.9 /BA/Wartung/Druckluftbehälter/Beschädigte Druckluftbehälter austauschen @ 12\mod_1224145015309_78.doc @ 151057
Note
Have damaged compressed air reservoirs replaced by a specialist's workshop