![Krone Big Pack 1270 HS Скачать руководство пользователя страница 144](http://html1.mh-extra.com/html/krone/big-pack-1270-hs/big-pack-1270-hs_original-operating-instructions_2004791144.webp)
KRONE ISOBUS-Terminal CCI 100
144
Pos: 24.177 /BA/Info-Center/Großpackenpresse/Hauptmenüs/Alarmmeldungen/5) Alarmmeldungen Tabelle allgemein 114-125 HS Baureihe @ 64\mod_1300117151504_78.doc @ 580168
No. Screen
Description
Possible
cause
Remedy
114
Hydraulic
pressure sensor
Sensor or supply line defective
- Perform a sensor test
- Check the sensor and line for
damage.
115
Sensor for setting
down bales
Sensor or supply line defective
- Perform a sensor test
- Check the sensor and line for
damage.
116
Sensor for bale
ejector
Sensor or supply line defective
- Perform a sensor test
- Check the sensor and line for
damage.
117
Star wheel sensor
Sensor (rotary potentiometer) or
line defective
- Perform a sensor test
- Check the sensor and line for
damage.
118
Pick-up sensor
Sensor or supply line defective
- Perform a sensor test
- Check the sensor and line for
damage.
119
Bale chute up
feeler
Feeler or supply line defective
- Perform a sensor test
- Check the feeler and line for
damage.
120
Bale chute down
feeler
Feeler or supply line defective
- Perform a sensor test
- Check the feeler and line for
damage.
121
Bale ejector feeler
out
Feeler or supply line defective
- Perform a sensor test
- Check the feeler and line for
damage.
122
Bale ejector feeler
in
Feeler or supply line defective
- Perform a sensor test
- Check the feeler and line for
damage.
123
Blade bar up
feeler
Feeler or supply line defective
- Perform a sensor test
- Check the feeler and line for
damage.
124
Blade bar down
feeler
Feeler or supply line defective
- Perform a sensor test
- Check the feeler and line for
damage.
125
MultiBale sensor
Sensor (rotary potentiometer) or
line defective
- Perform a sensor test
- Check the sensor and line for
damage.
Pos: 24.178 /BA/-----Seitenumbruch------ @ 0\mod_1196175311226_0.doc @ 4165