KRONE ISOBUS-Terminal CCI 100
140
Pos: 24.171 /BA/Info-Center/Großpackenpresse/Hauptmenüs/Alarmmeldungen/2) Alarmmeldungen Tabelle allgemein 0 - 9 @ 19\mod_1238504387040_78.doc @ 220236
No. Image
Description
Possible
cause
Remedy
0
Twine monitoring
- Twine torn
- Twine end
Checking the twine and twine
tensioner
1
Packer monitoring
Blockage in the intake area of the
packer
Stop the traction drive immediately
Reduce P.T.O. speed until the
blockage is cleared
2
Pressing force
exceeded, left
sensor
Pressing force exceeded
If the machine could be subject to
a mechanical overload because
the pressure is too high, the bale
channel flap pressure is lowered
to a non-critical value just before
the overload. The amount of
reduction depends on the
material being baled. The
reduction is less for straw than for
silage.
The following measures must be
taken:
1
.
In manual mode:
-Lower the pressure
2
. In Automatic mode:
If the alarm occurs quite
frequently, reduce the pressing
force setting slightly
3
Force of
pressure
exceeded, right
sensor
4
Knotter
monitoring
- Knotter is not functioning
properly
- Sensor set incorrectly
- Check the knotter and knotter
triggering
- Set the knotter monitoring sensor
correctly
5
Measurement
monitoring
Sensor measuring defective or
set incorrectly
Adjust the sensor correctly
6
Calibration
monitoring
Sensor calibration defective or set
incorrectly
Adjust the sensor correctly
7
Flywheel brake
Flywheel brake applied
Release the flywheel brake
8
Needle
connecting rod
Shear screw ruptured
- Replace the shear screw
- Check needles
- Check the swivel range of the
needles
- Check the twine guide
9
Bale chute
Bale chute up and P.T.O. shaft is
turning
- Lower bale chute