8.13
Indicating the baling pressure via the electronic baling pressure indicator
72
Bellima F 130
Original Operating Instructions 150000148_06_en
8.13
Indicating the baling pressure via the electronic baling pressure
indicator
For the "Electronic baling pressure indicator" version
RP000-209
The indicator lamps (1) and (2) indicate how the baling pressure is built up. The indicator lamps
(1) and (2) light up until the set baling pressure is reached on both sides.
The baling pressure must be reached both on left (1) and on right (2) in the round bale. Both
indicator lamps must have gone out before a tying cycle can be triggered,
.
To set the baling pressure,
8.14
Actuating the hydraulic switching valve
If only one hydraulic connection is provided at the tractor, you can change between the
hydraulic operation of the tailgate and the hydraulic operation of the pick-up.
RP000-087
Position
Hydraulic operation
[I]
Opens/closes the tailgate
[II]
Bringing the pick-up to transport/working position
ü
The operating cable (2) is correctly guided to the tractor,
From the tractor, pull the operating cable (2).
Æ
The display (1) changes to the desired position [I] or [II].
Æ
Via the tractor hydraulics, the tailgate can be open/closed,
, or the pick-up
can be brought into transport/working position,