![Krone Bellima F 130 Скачать руководство пользователя страница 110](http://html1.mh-extra.com/html/krone/bellima-f-130/bellima-f-130_original-operating-instructions_2004784110.webp)
11
Maintenance
11.16 Cleaning the machine
110
Bellima F 130
Original Operating Instructions 150000148_06_en
RP000-195
If the distance between the roller (1) and the bale formation conveyor chain is changed, the
deflector sheets (2) must also be reset on the right and left sides of the machine inside the bale
chamber.
The deflector sheets must be positioned close to the roller (1).
Make the following setting on the right and left sides of the machine in the same way:
Loosen the screws (3) and the deflector sheet (2) in the oblong hole until the deflector
sheet (2) is positioned close to the roller (1).
Tighten the screws (3).
11.16
Cleaning the machine
WARNING
Eye damage caused by flying dirt particles!
When cleaning the machine with compressed air or with high-pressure cleaner, the dirt
particles are slung away at high speed. The dirt particles may hit the eyes and hurt them.
Keep persons away from working range.
When performing cleaning work with compressed air or with high-pressure cleaner, wear
suitable working clothes (for example eye protection).
ü
The machine is shut down and safeguarded,
.
After each use, clean the entire area around the tying unit.
Also after each use, clean all moving parts on the brake linkage and brake lever with
compressed air, e.g. piston rod, brake lever and slack adjuster. This can prevent mechanical
blockages.