12
Disturbance, cause and remedy
12.7
Checking and adjusting the starter roll and the pressure rolls
120
Bellima F 130
Original Operating Instructions 150000148_06_en
RP000-190
If the two twines are not cut off simultaneously at the cutting unit, you can change the position of
the cutter blades (5). To do so, the cutter blade (5) which cuts the twine too late must be
positioned further outwards.
ü
The cutting unit has been cleaned,
Loosen the respective screw (3) at the blade guide (2).
Bring the respective eccentric plate (4) into the desired position.
Tighten the respective screw (3).
12.7
Checking and adjusting the starter roll and the pressure rolls
RP000-138
Rotate the starter roll (1) slightly in order to check whether the pressure rolls (3) rotate
easily.
If the pressure rolls (3) fail to rotate smoothly:
Push a screwdriver between the drive roll (1) and pressure rolls (3) and lightly move from
left to right.
If necessary, loosen the screw connection (2) and oil the bearing positions.
12.8
Changing O-ring seal on the twine coil starting device
If the O-ring seal on the twine coil starting device is defective, the twine will not be injected
when tying starts. The O-ring seal must be changed.